Free phone consult with a 25-year leak expert. Call 604-239-9934

EM Line Locating · Power · radio frequency · Metro Vancouver

Passive EM Sweep Locating in Burnaby, BC

Sweep an area for the signals buried metal already carries — live power at 50/60 Hz and re-radiated radio energy — to catch energised and conductive lines before a dig, without connecting to anything. The fast first pass that makes sure nothing live gets missed. Serving Burnaby and the Metro Vancouver since 1999 — EM and GPR run together.

Power + radio
Two passive frequency bands
No connection
Detects existing signals only
Area sweep
Coverage before targeted tracing

Free phone consult · No pressure · Mon–Sat 8am–6pm PT

Burnaby context that shapes the locate

Ground conditions: Till slopes give clean 2–3 m penetration; peat and high water table near Burnaby Lake and Big Bend cut effective depth — survey design accounts for it.

Local stock: Metrotown and Brentwood tower clusters on post-tensioned slabs, 1960s–70s walk-ups mid-slope, and heavy industrial along the Fraser.

Best suited for

  • Initial sweep of a dig area for unknown utilities
  • Catching energised power before excavation
  • Screening before active tracing and GPR
  • Quick presence/absence checks across a site

How passive sweep locating runs in Burnaby

  1. 1

    Power-mode sweep

    The receiver is set to 50/60 Hz and swept across the area — energised power cables and any metal carrying stray power current announce themselves first, because they're the lines you least want to find with a shovel.

  2. 2

    Radio-mode sweep

    Switching to the radio band catches long conductive lines re-radiating ambient radio energy — adding pipes and cables that aren't energised but are still detectable passively.

  3. 3

    Flag the field

    Everything the passive sweep finds is flagged. Passive can't identify which line is which, so flags mark presence, not identity — the cue for where active tracing and GPR go next.

  4. 4

    Hand off to active + GPR

    Active locating then traces each known target precisely and GPR images the non-conductive lines passive can't see. Passive opens the locate; it never closes it alone.

Burnaby questions, answered

How does Burnaby ground affect EM and GPR locating?

EM line tracing is largely soil-independent — it follows the signal on the conductor regardless of what's around it — but GPR, the half that finds non-conductive plastic and clay lines, is very soil-sensitive. Burnaby sits on predominantly glacial till slopes with peat pockets around Burnaby Lake and Big Bend. Till slopes give clean 2–3 m penetration; peat and high water table near Burnaby Lake and Big Bend cut effective depth — survey design accounts for it. So in Burnaby we lean on EM for the metal and tracer-wired lines and set realistic GPR expectations for the plastic — which is exactly why running both methods matters here.

What gets located most around Burnaby?

The local mix follows the building stock: Metrotown and Brentwood tower clusters on post-tensioned slabs, 1960s–70s walk-ups mid-slope, and heavy industrial along the Fraser. Underneath that, the everyday Burnaby locate is private water and irrigation services, power to outbuildings and gates, gas to outdoor features, and the plastic mains that need GPR or sonde tracing — the private-side utilities no public locate covers.

Do I still need a private locate in Burnaby if I called BC One Call?

Yes. BC One Call marks member utilities' public lines to the property line across Burnaby and all of BC — it does not locate the private services beyond it, which is where most strikes happen. The EM + GPR clearance survey covers those private lines. Use both: BC One Call for the public locates, a private dual-method locate for everything on your side.

What does EM + GPR locating cost in Burnaby?

Province-wide pricing — no regional premium for Burnaby or anywhere in the Metro Vancouver. A focused clearance (a dig area, a fence line) starts in the low-to-mid hundreds; full-site mapping and SUE-grade work are quoted by scope. The free phone consult (604-239-9934) gives a firm number in about five minutes. Mon–Sat, 8am–6pm PT.

Why run a passive sweep if it can't identify lines?

Because its job is safety-first discovery, not identification. The power-mode sweep flags energised cables — the highest-consequence strike risk — before anyone applies a signal or breaks ground, and the radio sweep catches conductive lines you didn't know were there. It's the fast opening pass that tells the active-locating and GPR work where to concentrate.

Does passive locating find plastic pipe?

No — passive detection needs the line to carry or re-radiate a signal, and bare plastic carries nothing. Plastic water mains, PVC/clay sewer, and similar non-conductive utilities are invisible to every EM mode; they're found by GPR imaging or by tracing a tracer wire or sonde. A passive 'all clear' is never a real all-clear on its own, which is exactly why we never stop there.

Need passive em sweep locating in Burnaby?

Free phone consult — what's underground, what you're digging, and a firm quote in five minutes.

Related content

Related guides, comparisons & specialist hubs

Internal navigation map for visitors and search engines — every Leak.ca pillar is one click away.